Collars will accept ULP, UPS, or MPS Spreaders
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL     
HEIGHT
LENGTH
WEIGHT
A
25
B
45
C
60
C
80
3L46
4'
6'
621
48
27
21
16
3L48
4'
8'
789
36
21
16
13
3L410
4'
10'
959
23
14
11
9
3L412
4'
12'
1,270
14
9
7
6
3L66
6'
6'
878
53
31
24
19
3L68
6'
8'
1,117
34
20
16
13
3L610
6'
10'
1,249
22
13
11
9
3L612
6'
12'
1,707
14
9
7
6
3L86
8'
6'
1,138
49
29
23
18
3L88
8'
8'
1,446
33
20
16
13
3L810
8'
10'
1,755
22
14
11
10
3L812
8'
12'
2,205
14
10
8
7


3" STEEL SINGLEWALL SHIELDS
Collars will accept ULP, UPS, or MPS Spreaders
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL     
HEIGHT
LENGTH
WEIGHT
A
25
B
45
C
60
C
80
3M46S
4'
6'
967
94
54
42
32
3M48S
4'
8'
1,153
47
28
22
17
3M410S
4'
10'
1,341
27
17
14
11
3M412S
4'
12'
1,528
18
12
10
8
3M66S
6'
6'
1,272
76
44
34
27
3M68S
6'
8'
1,528
42
25
20
16
3M610S
6'
10'
1,784
27
17
14
11
3M612S
6'
12'
2,041
18
12
10
8
3M86S
8'
6'
1,618
42
25
20
16
3M88S
8'
8'
1,943
32
20
16
13
3M810S
8'
10'
2,269
27
17
14
11
3M812S
8'
12'
2,594
20
13
11
9


3" STEEL DOUBLEWALL SHIELDS
Collars will accept ULP, UPS, or MPS Spreaders
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL     
HEIGHT
LENGTH
WEIGHT
A
25
B
45
C
60
C
80
3M66D
6'
6'
1,475
114
65
50
38
3M68D
6'
8'
1,966
85
49
38
29
3M610D
6'
10'
2,284
68
40
31
24
3M612D
6'
12'
2,648
56
33
26
20
3M86D
8'
6'
2,100
63
37
29
22
3M88D
8'
8'
2,436
47
28
22
17
3M810D
8'
10'
2,927
37
22
18
14
3M812D
8'
12'
3,403
32
20
16
13

*** PSF Ratings and depths are based on short term exposure with excavation open a period of time equal to 24 hours or less. Consult manufacturer should long term exposure be required. Depths are based on A, B, C soil types are described in OSHA's 29 CPR Part 1926 Subpart P, October 31, 1989 with Type A not exceeding 25 PSF per foot of depth. Type B not exceeding 45 PSF per foot of depth. Type C-60 not exceeding 60 PSF per foot of depth and Type C-80 not exceeding 80 PSF per foot of depth. Determine actual soil pressures and consult Manufacturers Tabulated Data prior to each use.




SPREADER SET SELECTION

ULPS (LIGHT PIPE SPREADERS)
1/4" WALL STEEL PIPE
(4) 4" SCHEDULE 40 PIPES
(INCLUDES PINS & KEEPERS)
MODEL# WIDTH WEIGHT
ULPS-4-24
24"
110#
ULPS-4-30
30"
135#
ULPS-4-36
36"
155#
ULPS-4-42
42"
175#
ULPS-4-48
48"
200#
ULPS-4-54
54"
225#
ULPS-4-60
60"
255#
ULPS-4-72
72"
290#
ULPS-4-84
84"
345#
ULPS-4-96
96"
395#
ULPS-4-120
120"
490#
ULPS-4-132
132"
795#
ULPS-4-144
144"
855#
LPS (LIGHT PIPE SPREADERS)
5/16" WALL STEEL PIPE
(4) 4" SCHEDULE 80 PIPES
(INCLUDES PINS & KEEPERS)
MODEL# WIDTH WEIGHT
LPS-4-24
24"
150#
LPS-4-30
30"
180#
LPS-4-36
36"
210#
LPS-4-42
42"
240#
LPS-4-48
48"
270#
LPS-4-54
54"
300#
LPS-4-60
60"
330#
LPS-4-72
72"
390#
LPS-4-84
84"
450#
LPS-4-96
96"
480#
LPS-4-120
120"
540#
MPS (MEDIUM PIPE SPREADERS)
3/8" WALL STEEL PIPE
(4) 5" SCHEDULE 80 PIPES
(INCLUDES PINS & KEEPERS)
MODEL# WIDTH WEIGHT
MPS-4-24
24"
230#
MPS-4-30
30"
275#
MPS-4-36
36"
320#
MPS-4-42
42"
360#
MPS-4-48
48"
400#
MPS-4-54
54"
440#
MPS-4-60
60"
480#
MPS-4-72
72"
650#
MPS-4-84
84"
750#
MPS-4-96
96"
850#
MPS-4-120
120"
1025#
MPS-4-132
132"
1150#
MPS-4-144
144"
1250#