STEEL

AVAILABLE IN 4", 6" OR 8" WALL THICKNESS

 

COMPLIES WITH LATEST OSHA REGULATIONS

MULTI-PURPOSE
USE DROP BOXES TO INSTALL:
  • MANHOLES
  • CATCH BASINS
  • SEEPAGE BASINS
  • ELECTRICAL VAULTS
  • SIMILAR STRUCTURES
PROFESSIONAL ENGINEER CERTIFIED
HIGH STRENGTH STEEL CONSTRUCTION
4", 6" or 8" WALL THICKNESS - STANDARD (OTHER WALL THICKNESSES AVAILABLE)
CHOICE OF SINGLEWALL OR DOUBLEWALL CONSTRUCTION
UTILIZES PINNED IN PIPE SPREADERS
LIFTING LUGS STANDARD
HARDWOOD FILLED TOP
REINFORCED BOTTOM CUTTING EDGES AND ANTI-WEAR BAR STANDARD
STACKABLE






Call for the American Shoring Distributor nearest you

1-800-407-4674

Fax: 1-800-361-1973 E-Mail us at MightyLite@aol.com

STEEL MANHOLE SHIELD SELECTION

4" SINGLEWALL OPEN ENDS
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL
HEIGHT
LENGTH
*PC
WEIGHT
A
B
C-60
C-80
4SMH88SW
8'
8'
48"
2800#
34
19
15
12
4SMH810SW
8'
10'
48"
2900#
26
16
13
10
4SMH812SW
8'
12'
48"
3400#
23
13
10
9
CHOOSE WIDTH FROM SPREADER SET SELECTION BELOW
*PC = Pipe Clearance under spreaders is approximate depending on spreader set selection to be used.


4" DOUBLEWALL OPEN ENDS
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL
HEIGHT
LENGTH
*PC
WEIGHT
A
B
C-60
C-80
4SMH88DW
8'
8'
48"
3300#
71
39
30
25
4SMH810DW
8'
10'
48"
4000#
68
38
28
24
4SMH812DW
8'
12'
48"
4600#
61
34
26
22
4SMH814DW
8'
14'
48"
5400#
57
32
24
20
CHOOSE WIDTH FROM SPREADER SET SELECTION BELOW
*PC = Pipe Clearance under spreaders is approximate depending on spreader set selection to be used.


6" SINGLEWALL OPEN ENDS
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL
HEIGHT
LENGTH
*PC
WEIGHT
A
B
C-60
C-80
6SMH88SW
8'
8'
48"
4200#
48
26
20
16
6SMH810SW
8'
10'
48"
4700#
38
21
16
14
6SMH812SW
8'
12'
48"
5200#
28
16
12
10
6SMH814SW
8'
14'
48"
5900#
23
13
10
8
CHOOSE WIDTH FROM SPREADER SET SELECTION BELOW
*PC = Pipe Clearance under spreaders is approximate depending on spreader set selection to be used.

INSIDE CLEAR LENGTH IS APPROXIMATELY 2' LESS THAN OVERALL LENGTH.


*** PSF Ratings and depths are based on short term exposure with excavation open a period of time equal to 24 hours or less. Consult manufacturer should long term exposure be required. Depths are based on A, B, C soil types are described in OSHA's 29 CPR Part 1926 Subpart P, October 31, 1989 with Type A not exceeding 25 PSF per foot of depth. Type B not exceeding 45 PSF per foot of depth. Type C-60 not exceeding 60 PSF per foot of depth and Type C-80 not exceeding 80 PSF per foot of depth. Determine actual soil pressures and consult Manufacturers Tabulated Data prior to each use.



OTHER SIZES AVAILABLE

3 OR 4 SIDED UNITS MAY BE CONNECTED USING CONNECTOR BRACKETS.
CONTACT US FOR DETAILS.


4" SINGLEWALL WRAPAROUND ENDS
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL
HEIGHT
WIDTH
LENGTH
*PC
WEIGHT
A
B
C-60
C-80
4SMH88SWE
8'
8'
8'
45"
4500#
38
21
16
13
4SMH810SWE
8'
10'
10'
45"
5200#
28
18
14
12
4SMH812SWE
8'
10'
12'
45"
6000#
28
16
12
10
*PC = Pipe Clearance under spreaders is approximate depending on spreader set selection to be used.


4" DOUBLEWALL WRAPAROUND ENDS
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL
HEIGHT
WIDTH
LENGTH
*PC
WEIGHT
A
B
C-60
C-80
4SMH88DWE
8'
8'
8'
45"
4800#
81
45
34
23
4SMH810DWE
8'
10'
10'
45"
6000#
72
40
30
21
4SMH812DWE
8'
10'
12'
45"
7900#
62
35
26
18
*PC = Pipe Clearance under spreaders is approximate depending on spreader set selection to be used.



SPREADER SET SELECTION

MPS 5" SCHEDULE 80 PIPE
4-PIPE SPREADER SYSTEM
MODEL# WIDTH WEIGHT
MPS24M
24"
230#
MPS30M
30"
275#
MPS36M
36"
320#
MPS42M
42"
360#
MPS48M
48"
400#
MPS54M
54"
440#
MPS60M
60"
480#
MPS72M
72"
650#
MPS84M
84"
750#
MPS96M
96"
850#
MPS108M
108"
940#
MPS120M
120"
1025#
MPS144M
144"
1250#
HPS 8" SCHEDULE 80 PIPE
4-PIPE SPREADER SYSTEM
MODEL# WIDTH WEIGHT
HPS24M
24"
500#
HPS30M
30"
600#
HPS36M
36"
700#
HPS42M
42"
750#
HPS48M
48"
850#
HPS54M
54"
1000#
HPS60M
60"
1050#
HPS72M
72"
1250#
HPS84M
84"
1475#
HPS96M
96"
1650#
HPS108M
108"
1850#
HPS120M
120"
2000#
HPS144M
144"
2250#




Return to Products Page