AVAILABLE IN 6" OR 8" WALL THICKNESS

        

COMPLIES WITH LATEST OSHA REGULATIONS



DOUBLEWALL

SHOWN ABOVE WITH FIVE (5) PIPE SPREADER SYSTEM

PROFESSIONAL ENGINEER CERTIFIED
HIGH STRENGTH STEEL CONSTRUCTION
4", 6" or 8" WALL THICKNESS - STANDARD (OTHER WALL THICKNESSES AVAILABLE)
UTILIZES 8" SCHEDULE 80 PINNED IN PLACE STEEL PIPE SPREADERS
LIFTING LUGS BUILT INTO SIDEWALLS
HARDWOOD FILLED TOP & FRONT RAILS
REINFORCED BOTTOM CUTTING EDGES AND ANTI-WEAR BAR STANDARD
STACKABLE
INTERCHANGEABLE WIDTHS
OPTIONAL STYROFOAM FILLED



DOUBLEWALL

SHOWN WITH FOUR (4)PIPE SPREADER SYSTEM. "H" STYLE BRACKETS PERMIT STACKING AND LOCKING OF BOXES TOGETHER. STACKING TUBES ALSO AVAILABLE.


Call for the American Shoring Distributor nearest you

1-800-407-4674

Fax: 1-800-361-1973 E-Mail us at MightyLite@aol.com

SIDE PANEL SELECTION

6" MEDIUM DUTY
DOUBLEWALL
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL
HEIGHT
LENGTH
WEIGHT
A
B
C-60
C-80
6M412D
4'
12'
3100#
102
71
54
42
6M416D
4'
16'
4500#
90
50
38
29
6M420D
4'
20'
5375#
55
32
24
19
6M424D
4'
24'
6450#
38
22
17
13
6M426D
4'
26'
6700#
34
20
16
12
6M612D
6'
12'
4500#
92
60
48
40
6M616D
6'
16'
5950#
86
49
37
29
6M620D
6'
20'
7100#
54
31
24
18
6M624D
6'
24'
8350#
38
23
18
15
6M626D
6'
26'
9000#
33
18
14
11
6M812D
8'
12'
6400#
84
42
35
28
6M816D
8'
16'
7700#
69
40
30
24
6M820D
8'
20'
9300#
57
32
24
19
6M824D
8'
24'
10675#
37
22
18
14
6M826D
8'
26'
11500#
32
19
14
9
6M1016D
10'
16'
9150#
76
42
32
24
6M1020D
10'
20'
11050#
57
33
26
20
6M1024D
10'
24'
12990#
40
24
19
15
6M1026D
10'
26'
13825#
32
21
14
11
     
6" HEAVY DUTY
DOUBLEWALL
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL
HEIGHT
LENGTH
WEIGHT
A
B
C-60
C-80
6H416D
4'
16'
5255#
99
70
53
41
6H420D
4'
20'
6319#
77
44
33
25
6H424D
4'
24'
7383#
53
31
23
18
6H616D
6'
16'
7133#
102
71
54
42
6H620D
6'
20'
8650#
79
45
34
26
6H624D
6'
24'
10168#
54
31
24
19
6H626D
6'
26'
10927#
46
27
21
16
6H628D
6'
28'
11634#
40
23
18
14
6H816D
8'
16'
9009#
93
54
41
32
6H820D
8'
20'
10981#
76
44
34
26
6H824D
8'
24'
12952#
55
32
25
20
6H826D
8'
26'
13938#
47
28
22
17
6H828D
8'
28'
14852#
41
24
19
15
6H1016D
10'
16'
10886#
86
50
39
30
6H1020D
10'
20'
13311#
70
41
32
25
6H1024D
10'
24'
15737#
55
33
26
21
6H1026D
10'
26'
16950#
48
29
23
18
6H1028D
10'
28'
18070#
41
25
20
16


8" MEDIUM DUTY
DOUBLEWALL
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL
HEIGHT
LENGTH
WEIGHT
A
B
C-60
C-80
8M412D
4'
12'
3250#
112
104
82
68
8M416D
4'
16'
4875#
98
77
58
49
8M420D
4'
20'
5875#
85
63
51
43
8M424D
4'
24'
6875#
66
51
43
39
8M426D
4'
26'
7350#
52
46
36
32
8M428D
4'
28'
7850#
49
38
30
23
8M612D
6'
12'
4650#
112
87
62
46
8M616D
6'
16'
6850#
99
66
50
39
8M620D
6'
20'
8275#
74
43
34
26
8M624D
6'
24'
9675#
51
30
23
19
8M626D
6'
26'
10500#
43
26
20
16
8M628D
6'
28'
12300#
38
23
18
15
8M812D
8'
12'
7200#
102
67
39
35
8M816D
8'
16'
8750#
80
48
36
30
8M820D
8'
20'
10575#
66
40
31
25
8M824D
8'
24'
12375#
52
30
24
18
8M826D
8'
26'
13400#
45
26
20
16
8M828D
8'
28'
14300#
40
24
19
15
8M1016D
10'
16'
10800#
97
60
46
35
8M1020D
10'
20'
13100#
80
47
37
29
8M1024D
10'
24'
15000#
56
34
27
22
8M1026D
10'
26'
16500#
47
29
23
18
8M1028D
10'
28'
17600#
42
26
21
16
     
8" HEAVY DUTY
DOUBLEWALL
APPROXIMATE
DIGGING DEPTH (FT.)
SOIL TYPE
MODEL
HEIGHT
LENGTH
WEIGHT
A
B
C-60
C-80
8H416D
4'
16'
5830#
99
93
70
53
8H420D
4'
20'
6982#
99
58
44
34
8H424D
4'
24'
8132#
71
40
31
23
8H616D
6'
16'
7812#
99
96
73
55
8H620D
6'
20'
9437#
99
60
46
35
8H624D
6'
24'
11062#
74
43
32
25
8H626D
6'
26'
11874#
62
36
28
21
8H628D
6'
28'
12638#
54
31
24
19
8H816D
8'
16'
9794#
99
57
44
34
8H820D
8'
20'
11892#
80
46
36
28
8H824D
8'
24'
13990#
68
39
31
24
8H826D
8'
26'
15040#
63
37
28
22
8H828D
8'
28'
16022#
55
33
26
21
8H1016D
10'
16'
11775#
102
59
46
36
8H1020D
10'
20'
14348#
81
47
37
29
8H1024D
10'
24'
16920#
68
40
31
25
8H1026D
10'
26'
18206#
63
37
29
23
8H1028D
10'
28'
19404#
55
33
26
21
*** PSF Ratings and depths are based on short term exposure with excavation open a period of time equal to 24 hours or less. Consult manufacturer should long term exposure be required. Depths are based on A, B, C soil types are described in OSHA's 29 CPR Part 1926 Subpart P, October 31, 1989 with Type A not exceeding 25 PSF per foot of depth. Type B not exceeding 45 PSF per foot of depth. Type C-60 not exceeding 60 PSF per foot of depth and Type C-80 not exceeding 80 PSF per foot of depth. Determine actual soil pressures and consult Manufacturers Tabulated Data prior to each use.


CUSTOM SIZES AVAILABLE INCLUDING 10" THICK SIDEWALLS FOR DEEP JOBS USING LARGE EXCAVATORS.
CONTACT US FOR DETAILS.



SPREADER SET SELECTION


HPS
HEAVY PIPE SPREADERS
FOR DEEP CUT
SIDEWALLS
(TAPER OPTIONAL)
(4) 8" SCHEDULE 80 PIPES
(INCLUDES PINS & KEEPERS)
MODEL# WIDTH WEIGHT
HPS 24
24"
500#
HPS 30
30"
600#
HPS 36
36"
700#
HPS 42
42"
775#
HPS 48
48"
850#
HPS 54
54"
950#
HPS 60
60"
1025#
HPS 72
72"
1200#
HPS 84
84"
1400#
HPS 96
96"
1550#
HPS 108
108"
1700#
HPS 120
120"
1900#

5-PIPE SPREADER SYSTEM
STANDARD FOR 10' HIGH SIDEWALLS
OPTIONAL FOR 8' HIGH SIDEWALLS
(TAPER OPTIONAL)
(5) 8" SCHEDULE 80 PIPES
(INCLUDES PINS & KEEPERS)
MODEL# WIDTH WEIGHT
HPS-5-24
24"
465#
HPS-5-30
30"
572#
HPS-5-36
36"
680#
HPS-5-42
42"
790#
HPS-5-48
48"
900#
HPS-5-54
54"
1005#
HPS-5-60
60"
1115#
HPS-5-72
72"
1480#
HPS-5-84
84"
1670#
HPS-5-96
96"
1920#
HPS-5-108
108"
2130#
HPS-5-120
120"
2350#




Return to Products Page